The impact of variability on power
Sani R. Nassif
ISLPED 2004
This paper presents a class of power grid analyzers based on a random-walk technique. A generic algorithm is first demonstrated for dc analysis, with linear runtime and the desirable property of localizing computation. Next, by combining this generic analyzer with a divide-and-conquer strategy, a single-level hierarchical method is built and extended to multilevel and "virtual-layer" hierarchy. Experimental results show that these algorithms not only achieve speedups over the generic random-walk method, but also are more robust in solving various types of industrial circuits. Finally, capacitors and inductors are incorporated into the framework, and it is shown that transient analysis can be carried out efficiently. For example, dc analysis of a 71 K-node power grid with C4 pads takes 4.16 s; a 348 K-node wire-bond dc power grid is solved in 93.64 s; transient analysis of a 642 K-node power grid takes 2.1 s per timestep. © 2005 IEEE.